search

 

Renewable Energy>
Prysmian Cables for photovoltaic systems - Lynisun

 

Current Carrying Capacity and Short-Circuit Current

 

Nominal cross-section (mm2)

1.5

2.5

4

6

10

15

25

35

Current Carrying Capacity - Free in air, 60°C ambient (A)

30

41

55

70

98

132

176

216

Short Circuit Current (kA)

0.19

0.32

0.50

0.76

1.26

2.01

3.15

4.41

 

 

Technical Parameters

 

Nominal cross-section (mm2)

Conductor Diameter

(mm)

Resistance

@ 20°C

W/km

Cable Diameter

(mm)

Nominal Weight

(kg/km)

Minimum Bend Radius

(mm)

Max. Tensile Load (N)

1.5

1.6

13.7

4.4 - 4.8

29

14

23

2.5

1.9

8.21

4.7 – 5.1

43

15

38

4

2.4

5.09

5.2 – 5.6

58

17

60

6

2.9

3.39

5.7 – 6.1

77

18

90

10

4.0

1.95

6.8 – 7.2

120

22

150

16

5.5

1.24

8.3 – 9.0

178

36

240

25

6.4

0.795

10.0 – 10.7

273

43

375

35

7.5

0.565

11.1 – 11.8

364

47

525

 

Cable Codes

 

Nominal cross-section (mm2)

DCC Description

DCC PN

1*1.5

1*1.5-LYNISUN-PV1-F

PFX37660

1*2.5

1*2.5-LYNISUN-PV1-F

PFX37670

1*4

1*4-LYNISUN-PV1-F

PFX37680

1*6

1*6-LYNISUN-PV1-F

PFX37690

1*10

1*10-LYNISUN-PV1-F

PFX37700

1*16

1*16-LYNISUN-PV1-F

PFX37710

1*25

1*25-LYNISUN-PV1-F

PFX37720

1*35

1*35-LYNISUN-PV1-F

PFX37730

   

Prysmian and DCC reserve the right to alter the products described in this data sheet without prior notice


בניית אתרים  Site Builder
 
  
 

DCC – Duchovni Communications Cables - Advanced Cabling and Connectivity Solutions

POB 25008, 17 Hamashbir St. Haifa 31250 Israel , Tel. +972-4-881-8404, Fax +972-4-881-8405