search

 

Transportation Cables>
Indusi signaling cable
  

Eisnebahn Bundesahmt

 

 

 

 

 





Application

·       For track control and magnet switching in railways

·       For direct burial, instllation in ducts or tunnels

 

Standards

·       Dlk 1.013.200
See certifications above

Construction

 

Conductors

Solid annealed copper, 0.8 mm

Insulation

Foam-skin PE

Twisting

Star quads stranding

Color code

See color code table

Core covering

Non-hygroscopic plastic tape

Contact wire

Tinned copper, solid, 0.6 mm, soft annealed

Screen

Aluminum tape 0.08 mm and Al/PET-foil 0.05 mm

Inner Jacket

Black PVC

Covering

2 layers of  crepe paper

Armor

Steel tape 0.3 mm thick, gap £ 2 mm, separating foil

Outer Jacket

Black UV-protected PVC

Printing

Per customer request

 

Mechanical, Thermal, and Environmental Properties                 

 

Bending radius - dynamic

200 mm

Bending radius - static

100 mm

Operation temperature range

-30° to +70°C

Tensile strength

300 N

 

Electrical Properties (20°C)

 

Conductor loop resistance

£ 73.2 W/km

Insulation resistance

³ 10 GW*km

Mutual capacitance @ 800 Hz

£ 30 nF/km

Capacitance unbalance @ 800 Hz

£ 400 pF/300 m

Test Voltage @ 50 Hz, 1 min: 

 

Core/core

500 V

Core/screen

2000 V

 

Cable Codes and Technical Parameters

 

Number of Pairs

DCC Cable Code

DCC PN

Nominal Dimensions (mm)

Nominal Weight (kg/km)

40

4x1x0.8-B-FS-VQV-ES

RRL24360

18

360

 

DCC reserves the right to alter the products described in this data sheet without prior notice  

 RL-8-FS-VQV-001

 020110-A

 55e 5.4.06

 

בניית אתרים  Site Builder
 
  
 

DCC – Duchovni Communications Cables - Advanced Cabling and Connectivity Solutions

POB 25008, 17 Hamashbir St. Haifa 31250 Israel , Tel. +972-4-881-8404, Fax +972-4-881-8405

© Copyright DCC Ltd. 